OPINION-SURVEYS.DE ≡ Šali Bracelets Rokavice Product
  • Ruixu

  • RUiXU RX-LFP48100-H 19″ Server Rack 3U Battery UL1973 Certified Self-Heating

RUiXU RX-LFP48100-H 19″ Server Rack 3U Battery UL1973 Certified Self-Heating

$33.25 $41.56
DescriptionThe self-heating 48V server rack battery is designed for usage in cold weather! Can safely charge at temperatures as low as -20°C (-4°F) by a standard charger or solar charger. The heated pads draw power from the charger itself. Support up to 32 units in parallel, scale from 5 kWh to 160 kWh configuration without external controller. 3U (133mm) standard height design Use DIP address to set the RS485 baud rate and inverter protocol choosing Comes with battery interconnection Amphenol connectors.   DetailsRated voltage: 51.2V Max. voltage range: 44.8~57.6V, Shipping voltage>51.2V Charge voltage: 56.0V Float charge voltage: 54.6V Low voltage cut-off: 44.8V Nominal energy: 5.12KWh Usable energy: 4.92kWh Nominal capacity: 100Ah Dimensions: 482*133.5*460mm (18.9*5.2*18.1 inch) Weight: ~50kg (110lbs) Standard charge current: ≤50A Max. charge current: 70A Standard discharge current: ≤50A Max. discharge current: 100A (initial temp. ≤35℃ [95°F]) Peak discharge current: 101~119A@5mins | 120~150A@5S Communication: RS485 /CAN Max parallel number: 32pcs Operation temperature1 Charge: 0~50℃ (32~122°F) Discharge: -20~50℃ (-4~122°F) Storage temperature: 0℃<T<30℃ (32°F<T<86°F)<6 months | -10℃<T<45℃ (14°F<T<113°F)<3 months Recommended environment: 15~35℃ (59~95°F), 5~75%RH Start heating: When the Minimum Cell temperature is between -25°C and 5°C (-13°F and 41°F), the battery is connected to the charger or inverter and the charging current is ≥ 0.05C*N, start heating. End heating: When the Minimum Cell temperature is above 12°C (53.6°F), end heating.  (1) The optimum operating temperature range is from 15°C to 30°C (15°F to 86°F). Frequent exposure to the harsh temperatures may worsen the performance of the battery pack and cycle life.   ModularSupport up to 32 units in parallel, scale from 5 kWh to 160 kWh configuration without external controller.  Inverter Protocol ChoosingUse DIP address to set the RS485 baud rate and inverter protocol choosing  CommunicationsCanbus: Victron, SMA, Studer Innotec, Sofar, Solark, Solis, Goodwe, Deye, Growatt, SAJ, LUXPOWER, Megarevo, INVT, Sermatec, TBB, MUST, Sunsynk, Schneider RS485: MPP, Voltronic, RCT, Alpha outback  Standard Included(1) RUiXU 48V Server Rack battery (RX-LFP48100-H) (1) RS485 Communication Cable  (1) Ground Cable  (1) Set of Parallel 4AWG Cables  per battery SKU:RX-LFP48100-H
Ruixu

Ruixu

  • RUiXU Lithi2-16 51.2V314Ah 16kWh LiFePO4 Battery Energy Storage
    $22.12 $37.38
  • RUiXU RX-LFP48100-H 19″ Server Rack 3U Battery UL1973 Certified Self-Heating
    $33.25 $41.56
  • RUiXU RS485 Battery Communication 3 Feet Cable
    $12.76 $18.5
  • RUiXU RX-LFP48100 19″ Server Rack 3U Battery UL1973 Certified UL9540 Pending
    $33.82 $44.64
  • RUiXU Single/Split-Phase Off-Grid Inverter – SUNON10 – 10kW – UL1741
    $21.47 $26.41
  • RUiXU 6 Slot Battery Cabinet – Wheels & Busbar Included – Pre-assembled
    $32.57 $62.53
  • RUiXU Split Phase Hybrid Inverter – RX-12K – UL1741
    $32.39 $62.51
  • RUiXU 30kWh Battery Kits RX-12K Inverter Bundles
    $25.47 $42.28
  • RUiXU 50kWh Battery Kits RX-12K Inverter Bundles
    $33.19 $58.75

© 2026 - OPINION-SURVEYS.DE