Sol-Ark 60K-3P-480V Hybrid Inverter System
$16.43
$26.62
DescriptionSol-Ark 60K Pre-Wired Hybrid Inverter System is a all-in-one system that includes an inverter, charger controller, a display with remote monitoring. The Sol-Ark is simple to install to a Grid-tied, Off-Grid, or Battery Backup solar system, while being able to manage power to and from Solar, Battery, Grid, Loads, and Generator.Especially designed for Commercial/Industrial Customers. Input Data (PV)Max. Allowed PV Power (STC): 78,000W Nominal Voltage Range: 150-850V Startup Voltage: 150V Max. Input Voltage1: 1,000V Max. Input Current per MPPT: 36A Max. short circuit current per MPPT: 55A No. of MPP Trackers: 4 No. of PV Strings per MPPT: 2 Max. AC Coupled Input: 120,000W Output Data (AC)Nominal AC Voltage (3Φ): 277/480V Grid Frequency: 50 / 60Hz Real Power, max continuous (3Φ): 60,000W Max. Output Current: 72.3A Peak Apparent Power (7s, off-grid, 3Φ): 120,000VA @ 144A Max. Grid Passthrough Current: 200A Power Factor Output Range: /- 0.8 adjustable Backup Transfer Time: 5ms (adjustable) CEC Efficiency: 96.5% Max Efficiency: 97.5% Design (DC to AC): Transformerless DC Stackable: Up to 12 in parallel Battery Input Data (DC)Battery Chemistry: Lithium iron phosphate No. of Battery Inputs: 2 Battery Input Terminal Rating: 50A Nominal DC Voltage: > 600V Operating Voltage Range: 160 – 800V Battery Capacity Range: 50 — 9900Ah Max. Battery Charge / Discharge Current: 100A (50A per input) Charge Controller Type: 3-Stage with Equalization Grid to Battery Charging Efficiency: 96.0% Automatic Generator Start (AGS): 2 Wire Start – Integrated BMS Communication2: CANBus & RS485 General DataDimensions (H x W x D): 894 x 528 x 295 mm (35.2 x 20.8 x 11.6 in) Weight: 79.4 kg (172 lb) Enclosure: IP65 / NEMA 3R Ambient Temperature: -40~60°C, > 45°C Derating Noise: < 30 dB @ 25°C (77°F) Idle Consumption – No Load: 60W Communication and Monitoring: Wi-Fi & LAN Hardware Included Warranty: 10 Years Additional InformationCertifications and Listings (Grid Support Interactive Inverter): UL 1741-2021 (incl UL1741SB), CSA C22.2 No 107.1-16, IEEE 1547-2018 & 1547a-2020 & 1547.1-2020 (SRD V2.0), L1699B, CEC3, SGIP3 PV DC Disconnect Switch — NEC 240.15: Integrated Ground Fault Detection — NEC 690.5: Integrated PV Rapid Shutdown Control — NEC 690.12: Integrated PV Arc Fault Detection — NEC 690.11: Integrated PV Input Lightning Protection: Integrated PV String Input Reverse Polarity Protection: Integrated Surge Protection: DC Type II / AC Type III 1) See Installation Guide for more details on sizing array strings, the highest input voltage is based on the voltage open-circuit of the array at the minimum design temperature.2) Active BMS communication is required for all lithium batteries. A list of compatible batteries can be found on our website.3) Currently pending listing.
Sol-Ark